08.11.2026 aktualisiert


100 % verfügbar
Engineering Manager Systems Integration | Cybersecurity Architect | Functional Safety Engineer
Essen, Deutschland
Weltweit
DiplomÜber mich
Senior Engineering Professional with 10+ years of international automotive experience in eMobility, E/E, cybersecurity, functional safety and regulatory compliance. Expert in vehicle systems, CRA implementation, engineering governance and global product development.
Skills
Automotive Open System ArchitectureFunktionale SicherheitSicherheitsanforderungen
Cyber Security in Detail:
- Deal with ISO/SAE 21434 Clause 8, 9, 10, 11 & 15 in day-day jobs. Performing TARA, Attack paths, Attack feasibility rating, Threat & Damage scenarios, Risk assessment and risk treatment decision to the item or component under development Deriving Cybersecurity goals, claims and requiements, cysec controls and develop cysec concept. I am providing technical support to hardware and software teams for complex security requirements, e.g., HSM Management, Secure Boot/Authenticated Boot, Flash Data Security/Downgrade Protection, Secure Onboard Communication, Vehicle Key Management System, SFD – Secure diagnostics, encrypted, communications/diagnostics, SecOC (AUTOSAR), CCC_v2, CeBID, , 0x27, 0x29, deactivation of XCP, Write, Memory By Address, JTAG; UART.
CSMS UNECE R155:
- CSMS type-approval-relevant E/E architecture. In order to meet the requirements, the topic of type-approval-relevant E/E architecture also had to be considered. An important preparatory work is the examination for "critical elements" according to UN-R 155, 7.3.3. Therefore, it is important to distinguish whether an ECU is OTA (over-the-air software update capability) or has external interfaces: GNSS, GSM, Wireless Local Area Network, Bluetooth, NFC. The focus here is on ECUs from the Gateway and Connectivity Domaine. Testing and the topic of type approval are closely linked because the tests (PEN test) are also used to validate ECUs.
- Highly critical control units need Diagnostic Protocol Confermance Test, Diagnostic Flash Conformance Test, Functional JTAG test, ECU specific functional security tests, Fuzz testing (part of the penetration test), Component penetration testing.
- In cooperation with Vector Informatik, a standard security architecture was developed that enables the use of controls working with certificates. SecOC, CCCv2, CeBID. The SSA module operates together with the application layer in AUTOSAR stack.
- Euro 7 has an impact on R155 for Reduction of vehicle emissions, monitoring of fuel consumption, In-vehicle battery durability (complementing Battery Regulation). Cybersecurity is required to ensure a secure implementation and an active monitoring of the data. Software, components & systems impacted by Euro 7.
SUMS UNECE R156:
- New SW features must be identified and all work products in the CSMS process must be adjusted.
- SUMS was also a needed for OTA update. For a gateway control unit we created a function TARA for OTA, using the ITEMIS tool. We identified 20+ Damage Scenarios and about 50 Threat Scenarios.
- Deal with ISO/SAE 21434 Clause 8, 9, 10, 11 & 15 in day-day jobs. Performing TARA, Attack paths, Attack feasibility rating, Threat & Damage scenarios, Risk assessment and risk treatment decision to the item or component under development Deriving Cybersecurity goals, claims and requiements, cysec controls and develop cysec concept. I am providing technical support to hardware and software teams for complex security requirements, e.g., HSM Management, Secure Boot/Authenticated Boot, Flash Data Security/Downgrade Protection, Secure Onboard Communication, Vehicle Key Management System, SFD – Secure diagnostics, encrypted, communications/diagnostics, SecOC (AUTOSAR), CCC_v2, CeBID, , 0x27, 0x29, deactivation of XCP, Write, Memory By Address, JTAG; UART.
CSMS UNECE R155:
- CSMS type-approval-relevant E/E architecture. In order to meet the requirements, the topic of type-approval-relevant E/E architecture also had to be considered. An important preparatory work is the examination for "critical elements" according to UN-R 155, 7.3.3. Therefore, it is important to distinguish whether an ECU is OTA (over-the-air software update capability) or has external interfaces: GNSS, GSM, Wireless Local Area Network, Bluetooth, NFC. The focus here is on ECUs from the Gateway and Connectivity Domaine. Testing and the topic of type approval are closely linked because the tests (PEN test) are also used to validate ECUs.
- Highly critical control units need Diagnostic Protocol Confermance Test, Diagnostic Flash Conformance Test, Functional JTAG test, ECU specific functional security tests, Fuzz testing (part of the penetration test), Component penetration testing.
- In cooperation with Vector Informatik, a standard security architecture was developed that enables the use of controls working with certificates. SecOC, CCCv2, CeBID. The SSA module operates together with the application layer in AUTOSAR stack.
- Euro 7 has an impact on R155 for Reduction of vehicle emissions, monitoring of fuel consumption, In-vehicle battery durability (complementing Battery Regulation). Cybersecurity is required to ensure a secure implementation and an active monitoring of the data. Software, components & systems impacted by Euro 7.
SUMS UNECE R156:
- New SW features must be identified and all work products in the CSMS process must be adjusted.
- SUMS was also a needed for OTA update. For a gateway control unit we created a function TARA for OTA, using the ITEMIS tool. We identified 20+ Damage Scenarios and about 50 Threat Scenarios.
Erfahrung
Berufserfahrungmehr als 10 Jahre
Freelancer seit2017
Sprachen
DeutschMutterspracheEnglischverhandlungssicherPortugiesischverhandlungssicherSpanischgut
Projekthistorie
De-energizing the High-Voltage System
◦ Disconnect the vehicle from the high-voltage supply according to the manufacturer's procedure.
◦ Secure the system against reconnection.
◦ Verify the absence of voltage.
◦ Consider residual energy stored in components such as inverter capacitors.
Performing Work on High-Voltage Systems
◦ Diagnostics and fault finding.
◦ Maintenance and repair activities
◦ Replacement of HV components such
Carrying Out Measurements and Tests
◦ Voltage measurements
◦ Insulation resistance tests
◦ Functional tests of HV components
Leading operational role at Daimler Buses in developing the CRA Regulation (EU) 2024/2847 compliance strategy
• Justification for not including the airport bus in the UNECE R155 approval.
• Assessment of manufacturer obligations, intended purpose definitions, and market
placement requirements under the EU Cyber Resilience Act (CRA).
• Interpretation and implementation of cybersecurity regulatory requirements for connected
vehicle systems, battery technologies, and charging infrastructure.
• Support of product compliance activities throughout the complete lifecycle, from development
and market introduction to maintenance and post-market obligations
• Contribution to CRA auditor training in a startup environment
• Technical translation of CRA requirements into established automotive standards and processe
• Development of processes for vulnerability management, secure development, and
• compliance documentation
• Criticality and gap analysis for the Airfield Bus product group, including the creation of a CRA
Regulation (EU) 2024/2847 roadmap and cybersecurity compliance assessments.
• Conducting gap analyses to meet requirements of the EU Cyber Resilience Act (CRA)
• Designing and implementing guidelines, processes, and measures to ensure CRA compliance
• Defining and establishing processes for the Secure Development Lifecycle, patch management,
and vulnerability management
Cybersecurity Architect Component:
Responsibility for Cybersecurity activities according to ISO/SAE 21434, ISO24089UNECE R155 R156. Presently working with BMS Battery Domain (Chargers, Pantograph), Connectivity Domain and Brake Domain ABS EBS components.
Cybersecurity Architect Vehicle:
IBC HDEP25+ Samano E6/E7IBC Chassi and IBC HDEP25+ Chassi from Sao Bernado de Campo (Brasil) and SAMANO (Spain)
Cybersecurity Architect & Systems Integration Lead – Electric Bus Platforms
• Lead Cybersecurity Architect for Battery Management Systems (BMS), battery chargers, pantograph
charging systems and high-voltage vehicle architectures within electrified bus platforms.
• Responsible for cybersecurity engineering activities throughout the complete product lifecycle, from
concept and development to industrialization, production and aftersales.
• Conduct Threat Analysis and Risk Assessments (TARA) and derive cybersecurity goals, requirements,
controls and cybersecurity concepts in accordance with ISO/SAE 21434 and UNECE R155.
• Define and coordinate cybersecurity architectures for vehicle functions, ECUs, battery systems, charging
infrastructure and connected services.
• Support certification, assessments and audits related to UNECE R155/R156
• Prepare and maintain technical specifications, cybersecurity requirements and engineering guidelines
according to ISO/SAE 21434, ISO 24089, UNECE R155, R156 and vehicle-specific standards.
.
Zertifikate
S 01 633 Fachmodul Elektrofachkraft (EFK) e Citaro
Daimler Buses GmbH2026
S 81 626 Fachmodul Elektrofachkraft (EFK)
Daimler Buses GmbH2026
Automotive Cybersecurity Technology Specialist
Institute for Security and Safety GmbH2025
Cybersecurity Architect - Specialized Modules
Vector Consulting Services GmbH2025
Automotive Cybersecurity Engineer ISO/SAE 21434
TÜV Nord2022
Functional Safety Engineer ISO 26262:2018 (FSCP Level 1 certified by TÜV SÜD)
TÜV Süd2022